Hi Everyone,
I have a Crucial SSD, smartctl reports a couple of unknown attributes, any idea what they are, or should we ask the vendor?
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.3] (local build)

Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org



=== START OF INFORMATION SECTION ===

Device Model: Crucial_CT250MX200SSD1

Serial Number: 154711194417

LU WWN Device Id: 5 00a075 111194417

Firmware Version: MU03

User Capacity: 250,059,350,016 bytes [250 GB]

Sector Sizes: 512 bytes logical, 4096 bytes physical

Rotation Rate: Solid State Device

Form Factor: 2.5 inches

Device is: Not in smartctl database [for details use: -P showall]

ATA Version is: ACS-3 T13/2161-D revision 4

SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)

Local Time is: Fri Mar 4 00:41:15 2016 MST

SMART support is: Available - device has SMART capability.

SMART support is: Enabled



=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED



General SMART Values:

Offline data collection status: (0x80) Offline data collection activity

was never started.

Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever
been run.

Total time to complete Offline
data collection: ( 795) seconds.

Offline data collection

capabilities: (0x7b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine
recommended polling time: ( 2) minutes.

Extended self-test routine

recommended polling time: ( 5) minutes.

Conveyance self-test routine

recommended polling time: ( 3) minutes.

SCT capabilities: (0x0035) SCT Status supported.

SCT Feature Control supported.

SCT Data Table supported.



SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0

5 Reallocated_Sector_Ct 0x0032 100 100 010 Old_age Always - 0

9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 176

12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 27

171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

173 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 17

180 Unused_Rsvd_Blk_Cnt_Tot 0x0033 000 000 000 Pre-fail Always - 2591

183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0

184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0

187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0

194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/33)

196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0

197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0

198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0

199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0

202 Unknown_SSD_Attribute 0x0030 100 100 001 Old_age Offline - 0

206 Unknown_SSD_Attribute 0x000e 100 100 000 Old_age Always - 0

210 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

246 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 63785057

247 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 1994838

248 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 655635



SMART Error Log Version: 1

No Errors Logged



SMART Self-test log structure revision number 1

Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error

# 1 Vendor (0xff) Completed without error 00% 175 -

# 2 Vendor (0xff) Completed without error 00% 151 -

# 3 Vendor (0xff) Completed without error 00% 111 -

# 4 Vendor (0xff) Completed without error 00% 69 -

# 5 Vendor (0xff) Completed without error 00% 39 -



SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing

2 0 0 Not_testing

3 0 0 Not_testing

4 0 0 Not_testing

5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.


Thanks,
Reinoud.
Reinoud Koornstra
2016-03-04 07:54:57 UTC
Permalink
Ohh, I see the unknowns are resolved in version 6.5.I'll wait for it, Thanks.

From: ***@hotmail.com
To: smartmontools-***@lists.sourceforge.net
Date: Fri, 4 Mar 2016 07:48:04 +0000
Subject: [smartmontools-support] Attributes identification




Hi Everyone,
I have a Crucial SSD, smartctl reports a couple of unknown attributes, any idea what they are, or should we ask the vendor?
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.4.3] (local build)

Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org



=== START OF INFORMATION SECTION ===

Device Model: Crucial_CT250MX200SSD1

Serial Number: 154711194417

LU WWN Device Id: 5 00a075 111194417

Firmware Version: MU03

User Capacity: 250,059,350,016 bytes [250 GB]

Sector Sizes: 512 bytes logical, 4096 bytes physical

Rotation Rate: Solid State Device

Form Factor: 2.5 inches

Device is: Not in smartctl database [for details use: -P showall]

ATA Version is: ACS-3 T13/2161-D revision 4

SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)

Local Time is: Fri Mar 4 00:41:15 2016 MST

SMART support is: Available - device has SMART capability.

SMART support is: Enabled



=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED



General SMART Values:

Offline data collection status: (0x80) Offline data collection activity

was never started.

Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever
been run.

Total time to complete Offline
data collection: ( 795) seconds.

Offline data collection

capabilities: (0x7b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine
recommended polling time: ( 2) minutes.

Extended self-test routine

recommended polling time: ( 5) minutes.

Conveyance self-test routine

recommended polling time: ( 3) minutes.

SCT capabilities: (0x0035) SCT Status supported.

SCT Feature Control supported.

SCT Data Table supported.



SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 0

5 Reallocated_Sector_Ct 0x0032 100 100 010 Old_age Always - 0

9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 176

12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 27

171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

173 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 17

180 Unused_Rsvd_Blk_Cnt_Tot 0x0033 000 000 000 Pre-fail Always - 2591

183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0

184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0

187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0

194 Temperature_Celsius 0x0022 073 067 000 Old_age Always - 27 (Min/Max 16/33)

196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0

197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0

198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0

199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0

202 Unknown_SSD_Attribute 0x0030 100 100 001 Old_age Offline - 0

206 Unknown_SSD_Attribute 0x000e 100 100 000 Old_age Always - 0

210 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0

246 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 63785057

247 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 1994838

248 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 655635



SMART Error Log Version: 1

No Errors Logged



SMART Self-test log structure revision number 1

Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error

# 1 Vendor (0xff) Completed without error 00% 175 -

# 2 Vendor (0xff) Completed without error 00% 151 -

# 3 Vendor (0xff) Completed without error 00% 111 -

# 4 Vendor (0xff) Completed without error 00% 69 -

# 5 Vendor (0xff) Completed without error 00% 39 -



SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing

2 0 0 Not_testing

3 0 0 Not_testing

4 0 0 Not_testing

5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.


Thanks,
Reinoud.

Loading...